RPM to Radians Per SecondRPM to rad/s
Updated November 22, 202616 min read

Torque, Power and Speed: P = T × ω Explained

The torque power speed formula P = T × ω, derived step by step, with SI and imperial constants (9549, 5252), conversion tables and worked motor examples.

You have a motor nameplate in one hand and a load torque in the other, and the numbers refuse to agree. Plug RPM straight into P = T × ω and your answer comes out roughly 9.55 times too large, which is enough to oversize a drive by a full frame or to cook a winding. We have all made that slip once. Convert speed to rad/s first, then multiply, and every result below checks out.

Rotational Power Calculator

RPM & Torque to Horsepower Calculator

Convert rotational speed and shaft torque into mechanical power (Horsepower, kW, Watts) using P = τω.

Presets:
RPM
Calculated Output Power
399.99HP
Kilowatts (kW)298.27 kW
Metric Watts298,274 W
Angular Velocity (ω)549.99 rad/s
Torque (Metric / Imp)542.3 N·m
Notice: At ~5,252 RPM, Horsepower exactly equals Torque in lb-ft (400.0 HP = 400.0 lb-ft)!
Formula: P = τ × ω = (542.3 N·m) × (549.99 rad/s) = 298274 W (400.0 HP)

The full torque, power and RPM calculator solves for any one of the three quantities and prints every step in kW, hp, N·m and lb·ft. Before any power work, convert your shaft speed with the RPM to radians per second converter:

m

The torque power speed formula in one line

Power is the rate of doing work. For a straight-line push, work equals force times distance, so power equals force times velocity. For a rotating shaft, torque plays the role of force and angular velocity plays the role of velocity.

P = T × ω

Here P is shaft power in watts (W), T is torque in newton-metres (N·m) and ω is angular velocity in radians per second (rad/s). Every other version of the torque power speed formula, including the 9549 and 5252 shortcuts, is this single line with unit conversions folded in. Learn this one and the rest is bookkeeping.

Derivation from work and rotation

Picture a force F applied tangentially at radius r on a pulley. The torque is T = F × r. When the pulley turns through a small angle dθ in radians, the point of application travels an arc length ds = r × dθ, so the work done is dW = F × ds = F × r × dθ = T × dθ.

Divide both sides by the time interval dt. Work per unit time is power, and angle per unit time is angular velocity, which gives P = T × dθ/dt = T × ω. The arc length relation ds = r × dθ holds only when θ is measured in radians, and the whole derivation rests on it.

If you want the broader kinematics behind ω, angular acceleration and the Δθ/t form, our rotational motion guide builds them from first principles. For the energy stored in a spinning mass, which grows with ω squared, see the rotational kinetic energy calculator.

The radian requirement in P = T × ω

The radian is defined as the ratio of arc length to radius, so it is dimensionally a pure number. The BIPM SI Brochure lists the radian as a coherent derived unit equal to 1 m/m. Because of that definition, N·m × rad/s collapses cleanly to N·m/s, which is a joule per second, which is a watt.

RPM carries two hidden factors. A revolution is 2π radians, and a minute is 60 seconds. Multiply torque by RPM and you have silently scaled the result by 60/(2π) ≈ 9.549, with units of N·m per minute times revolutions that no SI unit accepts.

ω (rad/s) = RPM × 2π / 60 = RPM × π / 30

At 1,475 RPM, ω = 1,475 × π / 30 = 154.46 rad/s. At 3,000 RPM, ω = 314.16 rad/s. A full table of these conversions, with the derivation of π/30, lives in our RPM to radians per second formula guide. The NIST Guide to the SI (SP 811) also sets out the rules for writing these units, including the N·m symbol and the treatment of the radian in derived units.

The SI working form with RPM

Engineers rarely carry ω around on a spec sheet; nameplates and pump curves list RPM. Substitute ω = RPM × π / 30 into P = T × ω and you get a form that accepts RPM directly.

P (W) = T (N·m) × RPM × π / 30

Divide by 1,000 to express the result in kilowatts. The constant becomes 30,000/π, which equals 60,000/(2π) ≈ 9,549.3.

P (kW) = T (N·m) × RPM / 9549

Rearranged for torque, which is how most motor sizing starts, the same relation reads T = 9549 × P(kW) / RPM. The 9549 constant is π/30 and a factor of 1,000 wearing a disguise, nothing more. Use 9549.3 when you need four significant figures; 9550 appears in many European catalogues and introduces an error of under 0.01 percent.

The table below holds torque fixed at 100 N·m and shows how power scales with speed. Every row uses P = 100 × RPM × π / 30.

Shaft speed (RPM)ω (rad/s)Power at 100 N·m (kW)Torque per kW (N·m/kW)
75078.547.8512.73
1,000104.7210.479.55
1,500157.0815.716.37
1,800188.5018.855.31
3,000314.1631.423.18
3,600376.9937.702.65

Read the right-hand column carefully. A 750 RPM machine needs almost five times the torque of a 3,600 RPM machine to deliver the same kilowatt, and torque, along with the current and iron that produce it, is what sets frame size and cost. Low-speed motors are big motors.

The imperial form and the 5252 constant

In US practice, torque is quoted in pound-feet (lb·ft) and power in horsepower. One mechanical horsepower is defined as 33,000 ft·lbf per minute. A torque of T lb·ft acting through one revolution does 2π × T ft·lbf of work, so at N RPM the work rate is 2π × T × N ft·lbf per minute.

HP = T (lb·ft) × RPM / 5252

Divide 2π × T × N by 33,000 and the constant appears: 33,000 / (2π) ≈ 5,252.1. A side effect follows directly from the arithmetic. At exactly 5,252 RPM, horsepower and lb·ft are numerically equal, so every dyno chart plotted in those units shows the torque and power curves crossing there. Our torque and RPM to horsepower guide walks through that crossover on real engine data.

Mixed units cause most of the trouble. If your torque is in N·m and you want horsepower, either convert torque first or compute kilowatts and convert power at the end. Pick one path per calculation and stay on it.

Converting N·m to lb·ft and kW to hp

Two exact-enough factors cover nearly every conversion you will meet. One pound-foot equals 1.35582 N·m, and one mechanical horsepower equals 745.7 W. Their reciprocals are 0.73756 lb·ft per N·m and 1.341 hp per kW.

T (lb·ft) = T (N·m) × 0.73756 | P (hp) = P (kW) / 0.7457

The 745.7 W figure is the mechanical (imperial) horsepower. Metric horsepower (PS) is 735.5 W, and electrical horsepower is defined as 746 W, so a European data sheet and a US data sheet can differ by about 1.4 percent for the "same" horsepower. Check which one the source uses before you compare two motors.

Torque (N·m)Torque (lb·ft)Power (kW)Power (hp, 745.7 W)
107.3811.34
5036.887.510.06
10073.761520.12
500368.83749.62
1,000737.675100.6
2,0001,475110147.5

The left pair and right pair are independent; each row is two separate conversions. The kW values follow common IEC frame ratings so you can map a nameplate quickly.

Torque and speed curves for induction motors

A three-phase induction motor does not deliver constant torque across its speed range. Started across the line, it produces locked-rotor torque at zero speed, dips to a pull-up torque during acceleration, climbs to a peak called breakdown torque, then falls steeply toward zero as speed approaches synchronous speed. The motor settles where its curve crosses the load curve, usually a little below synchronous speed.

That small gap is slip. A four-pole motor on a 50 Hz supply has a synchronous speed of 1,500 RPM and might run at full load near 1,460 to 1,475 RPM; on 60 Hz the synchronous speed is 1,800 RPM and full-load speed sits around 1,750 to 1,775 RPM. Our electric motor speed guide covers poles, frequency and slip in detail.

The NEMA MG 1 standard defines design letters (A, B, C, D) that set minimum locked-rotor, pull-up and breakdown torques for each rating. General-purpose Design B motors are the common choice for pumps and fans, while Design C and D motors trade efficiency or slip for higher starting torque on hard-starting loads such as loaded conveyors and punch presses. Breakdown torque on Design B machines is commonly in the range of two to three times full-load torque, but take the actual figure from the manufacturer's curve.

Power along this curve is still P = T × ω at every point. Near zero speed the torque is high and the output power is close to zero, because ω is close to zero. Full nameplate power appears only at rated speed, which is the one point where rated torque and rated ω coincide.

Variable frequency drives and the constant-power region

On a variable frequency drive (VFD), a motor can typically hold rated torque from low speed up to base speed, so power rises linearly with speed in that band. Above base speed the drive runs out of voltage, flux weakens, and available torque falls roughly in proportion to 1/speed. Power stays roughly flat there, which is why that band is called the constant-power region.

The US Department of Energy motor systems program publishes tip sheets on applying VFDs to centrifugal pumps and fans, where load torque falls with the square of speed and power with the cube. Halve the speed of a centrifugal fan and the shaft power drops to about one eighth of its full-speed value. That cube law is the source of most of the energy savings attributed to VFDs.

Torque and speed curves for combustion engines

A piston engine behaves differently from an induction motor. It produces no torque at zero speed, needs a starter to reach idle, and develops a torque curve that rises to a broad peak in the middle of the rev range before falling as breathing losses and friction grow. The power curve, being T × ω, keeps climbing past the torque peak because speed rises faster than torque falls.

Peak power therefore always sits at a higher RPM than peak torque. Once torque drops faster than speed rises, in percentage terms, power peaks and turns down. A gearbox exists to keep the engine inside the band between those two peaks while the vehicle speed changes across a range of perhaps ten to one.

Gearboxes trade speed for torque

A gearbox cannot create power. It multiplies torque by the ratio and divides speed by the same ratio, so the product T × ω stays the same apart from friction losses. Write it as conservation of power with an efficiency factor η.

P_out = η × P_in | T_out = T_in × i × η | n_out = n_in / i

Here i is the reduction ratio and η is mechanical efficiency as a decimal. Helical stages typically run at 95 to 98 percent each, while worm gears can fall to 50 to 85 percent depending on ratio and lead angle. The gear ratio RPM calculator guide lists typical efficiencies by gear type, and the pulley and belt speed guide applies the same speed and torque logic to belt drives.

Think of a gearbox as a currency exchange for mechanical power. You hand over speed and receive torque at a fixed rate, and the efficiency figure is the commission the exchange keeps. Nobody walks out with more money than they brought in, and no gearbox output shaft carries more watts than the input shaft fed it.

Worked examples with full arithmetic

Each example below works in SI first and then cross-checks with the shortcut constant. If the two paths disagree beyond rounding, a unit slipped somewhere.

Example 1: torque of a 15 kW pump motor

A centrifugal pump uses a 15 kW, four-pole motor rated at 1,475 RPM on a 50 Hz supply. Find the full-load shaft torque in N·m and lb·ft.

  1. Convert speed: ω = 1,475 × π / 30 = 154.46 rad/s.
  2. Solve P = T × ω for torque: T = 15,000 / 154.46 = 97.11 N·m.
  3. Cross-check with the shortcut: T = 9549.3 × 15 / 1,475 = 143,240 / 1,475 = 97.11 N·m.
  4. Convert to imperial: 97.11 / 1.35582 = 71.62 lb·ft, and 15 kW / 0.7457 = 20.12 hp.

Both paths land on 97.11 N·m. Size the coupling and the shaft key for this torque, plus the service factor your coupling supplier specifies.

Example 2: output torque of a 10:1 gearbox

A 7.5 kW motor running at 1,460 RPM drives a 10:1 helical gear reducer with 96 percent efficiency. Find output speed, output power and output torque.

  1. Motor torque: T_in = 9549.3 × 7.5 / 1,460 = 71,620 / 1,460 = 49.05 N·m.
  2. Output speed: n_out = 1,460 / 10 = 146 RPM, so ω_out = 146 × π / 30 = 15.29 rad/s.
  3. Output power: P_out = 0.96 × 7,500 = 7,200 W.
  4. Output torque from power: T_out = 7,200 / 15.29 = 470.9 N·m.
  5. Cross-check from the ratio: 49.05 × 10 × 0.96 = 470.9 N·m.

The ratio multiplied torque almost tenfold while speed fell exactly tenfold. The missing 300 W leaves the gearbox as heat in the oil and housing, and on a continuous-duty reducer that heat sets the thermal rating.

Example 3: engine power from a dyno reading

A dyno records 300 lb·ft at 4,000 RPM. Find power in horsepower and kilowatts.

  1. Imperial shortcut: HP = 300 × 4,000 / 5252 = 1,200,000 / 5252 = 228.5 hp.
  2. SI path: T = 300 × 1.35582 = 406.75 N·m, and ω = 4,000 × π / 30 = 418.88 rad/s.
  3. Power: P = 406.75 × 418.88 = 170,380 W = 170.4 kW.
  4. Cross-check: 228.5 × 0.7457 = 170.4 kW.

The two routes agree to four significant figures. If you only had the kilowatt figure, 170.4 / 0.7457 returns the same 228.5 hp.

Common mistakes with P = T × ω

The arithmetic is simple, and the errors are almost always unit errors. Here are the ones that show up most often in student work and in sizing calculations.

  1. Using RPM directly in P = T × ω. Take Example 1 and multiply 97.11 N·m by 1,475 RPM: the result is 143,237, which looks like 143 kW for a 15 kW motor. The error factor is exactly 60/(2π) ≈ 9.549. Convert to rad/s every time.
  2. Using revolutions per second without the 2π. Dividing RPM by 60 gives rev/s, which is still not rad/s. At 1,475 RPM, 24.58 rev/s times 97.11 N·m gives 2,387 W, short by a factor of 2π ≈ 6.28.
  3. Mixing horsepower definitions. Treating a 735.5 W metric horsepower as 745.7 W introduces a 1.4 percent error, which matters on efficiency guarantees and test reports.
  4. Forgetting efficiency on gearboxes. Computing output torque as T_in × i ignores friction. On a worm drive at 70 percent efficiency, that assumption overstates output torque by about 43 percent.
  5. Using synchronous speed in place of actual speed. A four-pole 50 Hz motor runs below 1,500 RPM under load. Using 1,500 in place of 1,475 understates torque by about 1.7 percent on Example 1, small but avoidable.

Every item on that list is a unit or definition error, never a physics error. The question that remains is: where does a sizing calculation usually break first? Start with step one of any calculation: the speed conversion is the line to check before anything else.

Motor sizing workflow from load to nameplate

A clean sizing calculation follows a fixed order. Start with the load, find torque and speed at the shaft, convert speed to rad/s, compute power, then apply drive losses and service factor.

  1. Find the load torque at the driven shaft across the full speed range, including starting.
  2. Find the required driven speed and convert it to ω in rad/s.
  3. Compute shaft power with P = T × ω at the operating point.
  4. Divide by the efficiency of every gear stage or belt between motor and load.
  5. Select the next standard motor rating above the result, then confirm starting torque against the motor curve.

This order keeps every quantity in SI until the very end, which removes most opportunities for a conversion slip. Convert to horsepower or lb·ft only when you report the result.

Frequently Asked Questions

What is the torque power speed formula?

The base relation is P = T × ω, with P in watts, T in N·m and ω in rad/s. With RPM, use P (kW) = T (N·m) × RPM / 9549, or in imperial units HP = T (lb·ft) × RPM / 5252.

Why does P = T × ω need radians per second?

The radian is the SI unit that makes N·m × rad/s reduce to watts. RPM includes a factor of 2π per revolution and 60 seconds per minute, so using it directly inflates power by about 9.549.

Where does the 9549 constant come from?

It is 60,000 / (2π) ≈ 9,549.3. The 60 converts minutes to seconds, the 2π converts revolutions to radians, and the 1,000 converts watts to kilowatts.

How do I convert N·m to lb·ft and kW to hp?

Divide N·m by 1.35582 to get lb·ft, or multiply by 0.73756. Divide kW by 0.7457 to get mechanical horsepower, since 1 hp equals 745.7 W.

Does a gearbox increase power?

No. A gearbox multiplies torque by the ratio and divides speed by the same ratio, so power stays constant apart from friction losses. Output power equals input power times the gearbox efficiency.

Why do torque and horsepower curves cross at 5,252 RPM?

In the formula HP = T × RPM / 5252, setting RPM to 5,252 makes horsepower equal to torque in lb·ft. The crossing appears only when the chart uses hp and lb·ft on the same scale.

Ready to run the numbers?

Get your result instantly — private, in your browser.